RRNC 2.0 Radon Fan Types
Total Foundation Area
PIPE SIZE Nominal (I.D.) |
Less than 1600 sq. feet | 1600 to 2500 sq. feet | 2500 to 4500 sq. feet |
---|---|---|---|
Less than 149 sq. meters | 149 to 232 sq. meters | 232 to 418 sq. meters | |
(3 inch) [7.6 cm] |
Use Radon Fan Type: RF1 RF1 Minimum rating:* 50 cfm @ 0.5" WC [85m3/hr @ 125 Pa] |
Use Radon Fan Type: RF2 RF2 Minimum rating:* 75 cfm @ 1.0" WC [127m3/hr @ 250 Pa] |
Radon fan to be sized by a certified/licensed radon mitigator. |
(4 inch) [10 cm] |
Use Radon Fan Type: RF1 RF1 Minimum rating:* 50 cfm @ 0.5" WC [85m3/hr @ 125 Pa] |
Use Radon Fan Type: RF2 RF2 Minimum rating:* 75 cfm @ 1.0" WC [127m3/hr @ 250 Pa] |
Radon fan to be sized by a certified/licensed radon mitigator. |
* Radon Fan Types RF1 & RF2 minimum flow and pressure ratings are manufacturer specifications.
RadonAway RRNC 2.0 Radon Fans
RF1 Suitable | RF2 Suitable |
---|---|
RP140 | RP145 |
RP145 | RP260 |
XP151 | XP151 |
XP201 | - |
GX5A | GX5A |
LV175 | LV175 |